| MODEL | WP800-294280 |
| OUTPUT | Charge voltage | 29.4V±1% |
| Charge voltage range | 17.5-29.4V |
| Charge current | 200-240VAC | 28A±10% |
| 100-120VAC | 20A±10% |
| Pre-charge current | 20% of CC (constant current) |
| Charge-end current | 200-240VAC | ≤2.8A ±20% |
| 100-120VAC | ≤2.0A ±20% |
| Rated power | 200-240VAC | 823.2W |
| 100-120VAC | 588W |
| Recommended battery capacity Note.3 | 40 - 150Ah |
| Leakage current from battery (Typ.) | ≤1mA |
| CHARGE INDICATOR | LED | Red: battery capacity is less than 80%. Yellow: battery capacity is greater than 80%. Green:standby or battery is full |
| INPUT | Rated input voltage | 100 - 240VAC 50 / 60Hz |
| Input voltage range Note.4 | 90 - 264VAC |
| Power factor (Typ.) | PF>0. 96 @Full load |
| Input current (Typ.) | 6.8A@100VAC |
| Inrush current (Typ.) | Cold start 75A @230VAC |
| Standby input power | < 2.5W |
| Efficiency (Typ.) | 92% |
| PROTECTION | Short circuit Note.5 | Protection type : Shut down output |
| Over voltage | >4.35V*N |
| Reverse polarity | By internal relay |
| Over temperature | Shut down output, recovers automatically after temperature goes down |
| ENVIRONMENT | Working temperature | -10 - +40℃ (Refer to " Derating Curve") |
| Working humidity | 0 - 90% RH |
| Storage temperature, humidity | -40 - +70℃, 0 - 95% RH |
| Cooling | Fan convection |
| Vibration resistance | 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes |
| SAFETY & EMC (Note.6) | Max. temperature rise | < 30℃ on casing |
| Hi-Pot Insulation | i/p to o/p: 3000V (1 min) |
| Safety standards | IEC62368 |
| EMC Emission | Parameter | Standard | Test Level I Note |
| Conducted | EN55032 FCC PART15 | Class B |
| Radiated | EN55032 FCC PART15 | Class B |
| Harmonic Current | EN61000-3-2 | ..... |
| Voltage Flicker | EN61000-3-3 | ..... |
| EMC IMMUNITY | EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 |
| OTHERS | MTBF | 30000H |
| Dimension | 288*129.5*81.7mm (L*W*H) |
| Weight | 3750g |
| NOTE | 1.Modification for charger specification may be required for different battery specification. Please contact battery vendor and Green digital power for details. 2.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 3.This is Green suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation. 4.Derating may be needed under low input voltages. Please check the derating curve for more details. 5.This protection mechanism is specified for the case the short circuit occurs after the charger is turned on. 6.The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component power supplies." |