G1300-432270 Smart Charger for 12S 38.4V LiFePO4 Battery Pack
G1300-432270
| Input Voltage | 43.2V |
|---|---|
| Output | 27.0A |
| Charging Process | Pre-charge, CC, CV and Cut-off(four stages) |
| Charging Indicator | Red LED flashing: Error Red LED on: Charging (battery < 80%) Yellow LED on: Almost full (80%–99%) |
| Protections | OVP, OTP, SCP, RP |
| Safety Approval | CE |
| Dimensions & Weight | 278 x 145 x 47.7 mm / 1.8kg |
| Suitable Industry | Surveillance System |
LiFePO4 battery chargers
| MODEL | G1300-432270 | |||
| OUTPUT | Charge voltage | 43.2V±1% | ||
| Charge voltage range | 30.0-43.2V | |||
| Charge current @AC230V | 27A±10% | |||
| Pre-charge current | 5.4A±10% | |||
| Charge-end current | ≤2.7A ±20% | |||
| Max. output@AC120~240V | 1200W | |||
| Recommended battery capacity Note.3 | 27 - 270Ah | |||
| Leakage current from battery (Typ.) | ≤1Ma | |||
| CHARGE INDICATOR | Multi-color LED or LCD panel | Red LED flashing: Error Red LED on: Charging (battery < 80%) Yellow LED on: Almost full (80%–99%) Green LED on: Fully charged or standby LCD Digital Panel: Optional accessory | ||
| COMMUNICATION FUNCTION | CAN / 485 ; CAN is default. Note.1 | Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or our LCD display panel accessary to set these parameters. | ||
| INPUT | Rated input voltage | 100 - 240VAC 50 / 60Hz | ||
| Input voltage range Note.4 | 90 - 264VAC | |||
| Power factor (Typ.) | PF>0. 96 @full load | |||
| Input current (Typ.) | 14A@100VAC | |||
| Inrush current (Typ.) | Cold start 75A @230VAC | |||
| Standby input power | < 4W | |||
| Efficiency (full load @ AC230V ) | 94% | |||
| PROTECTION | Short circuit Note.5 | Protection type : Shut down output | ||
| Over voltage | >3.7V*N | |||
| Reverse polarity | By internal relay | |||
| Over temperature | Shut down output, recovers automatically after temperature goes down | |||
| ENVIRONMENT | Working temperature | -10 - +40℃ (Refer to " Derating Curve") | ||
| Working humidity | 0 - 90% RH | |||
| Storage temperature, humidity | -40 - +70℃, 0 - 95% RH | |||
| Cooling | Fan convection | |||
| Vibration resistance | 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes | |||
| SAFETY& EMC (Note.6) | Max. temperature rise | < 40℃ on casing | ||
| Hi-Pot Insulation | i/p to o/p: 3000V (1 min) | |||
| Safety standards | IEC62368 | |||
| EMC Emission | Parameter | Standard | Test Level I Note | |
| Conducted | EN55032 FCC PART15 | Class B | ||
| Radiated | EN55032 FCC PART15 | Class B | ||
| Harmonic Current | EN61000-3-2 | ..... | ||
| Voltage Flicker | EN61000-3-3 | ..... | ||
| EMC IMMUNITY | EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 | |||
| OTHERS | MTBF | 30000H | ||
| Dimension | 278*145*47.7mm (L*W*H) | |||
| Weight | 1800g | |||
| NOTE | 1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green digital power for details. 2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation. 4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curve for more details. 5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on. 6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component power supplies." | |||