G1300-360330(36V 33A) Power Adapter for Industrial & Automation Equipment
G1300-360330
| Input Voltage | 100~240V |
|---|---|
| Output | 36.0V 33.0A |
| LED Indicator | Bi-color LED; green indicates normal operation, red indicates heavy load |
| Multi-protection | OVP, OCP, OTP, SCP |
| Safety Approvals | CE |
| Dimensions & Weight | 278 x 145 x 48 mm / 1.8 kg |
| Applications | Industrial & Automation Equipment |
SPECIFICATION
| Model part number (P/N) | G1300-360330 | |||
| OUTPUT | Rating output voltage | 36V±5% | ||
| Output current range | 0-33A | |||
| Max. power @AC120V~240V | 1200W | |||
| Line regulation | 1% | |||
| Load regulation | 3% | |||
| Soft start time | 2000mS (Input:115VAC Output: Full load) | |||
| Rise-up time | 30mS (Input:115VAC Output: Full load) | |||
| Hold-on time | 15mS (Input:115VAC Output: Full load) | |||
| Voltage ripple (RMS) | <output voltage*1% (20MHz ,AC coupling mode, connected in parallel with 0.1uf ceramic capacitor and 47uf electrolytic capacitor) | |||
| LED display | Bi-color LED; green indicates normal operation, red indicates heavy load, flashing red indicates error | |||
| INPUT | Rated input voltage | 100 - 240VAC 50 / 60Hz | ||
| Input voltage range Note.2 | 90 - 264VAC | |||
| Power factor (Typ.) | PF>0. 96 @Full load | |||
| Input current (Typ.) | 14A@100VAC | |||
| Inrush current (Typ.) | Cold start 75A @230VAC | |||
| Standby input power | < 4W | |||
| Efficiency (Typ.) | 94% | |||
| PROTECTION | Short circuit | Protection type: Shut down output | ||
| Over voltage | Protection type: Shut down output (120%) | |||
| Over current | Protection type: Shut down output (110-160%) | |||
| Over temperature | Shut down output, recovers automatically after temperature goes down | |||
| ENVIRONMENT | Working temperature | -10 - +40℃ (Refer to " Derating Curve") | ||
| Working humidity | 0 - 90% RH | |||
| Storage temperature, humidity | -40 - +70℃, 0 - 95% RH | |||
| Cooling | Fan convection | |||
| Vibration resistance | 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes | |||
| SAFETY & EMC (Note.3) | Max. temperature rise | < 40℃ | ||
| Hi-Pot Insulation | i/p to o/p: 3000V (1 min) | |||
| Safety standards | IEC62368 | |||
| EMC emission | Parameter | Standard | Test Level I Note | |
| Conducted | EN55032 FCC PART15 | Class B | ||
| Radiated | EN55032 FCC PART15 | Class B | ||
| Harmonic Current | EN61000-3-2 | ..... | ||
| Voltage Flicker | EN61000-3-3 | ..... | ||
| EMC immunity | EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 | |||
| OTHERS | MTBF | 30000H | ||
| Size | 278*145*47.7mm(L*W*H) | |||
| Weight | 1800g | |||
| NOTES | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curve for more details. 3. The power supply is considered an independent unit, but the final equipment still needs to re-confirm that the whole system complies with the EMC directives. 4. AC Inlet is IEC320-C14; DC terminal is defined upon order. | |||