G100-36A Lead-acid Charger for 36V Pb-Acid/AGM/GEL/VRLA/WET battery
- Specification
- Input: 100~240V
- Output: 41.4V 1.8A
- Charge Process: CCăCV(H)ăPulse-Floating (Three stages)
- Charger Indicator: With 4 LEDs Battery Meter,20%~100%
- Output Protections: OVPăOCPăShortedăReversed
- Safety Approval: CE cTUVus CCC PSE
- Size: 175 x 72 x 40mm/400g
- Industry: Power ToolsăSecurity System
G100-
|
||
| Item | Specification | Remark |
| 1.Input | ||
| Rating input voltage | 100~240Vac 50/60Hz | |
| Input voltage range | 90~264Vac | |
| Rating input current | 1.5Arms | Input:100V Output:Full load |
| Max input power | 100W | Input:100V Output:Full load |
| 2.Output | ||
| No load output voltage | DC44.1V | |
| Output voltage range | DC30.0~44.1V | |
| Suit with battery type | 36V Pb-Acid battery | |
| Charging current | 1.8A ±10% | |
| Charging voltage | DC44.1V ±0.9V | |
| Floating charge voltage | DC39.6V-41.4V | ă |
| Charge-end current | â€0.3A±0.1A | |
| Timer | 10hours | |
| Max output power | 79.38W | ă |
| Ripple voltage | â€414mV | Full load |
| Power LED | Red | Power on |
| Charging LED | All off | No battery |
| All on | Full charge | |
| All flash | Error | |
| Flashing one by one | Charging | |
| Shorted | Yes | |
| Reversed | Yes | |
| Efficiency | â„87% | Full load @220V |
| 3.Environment | ||
| Operate temperature | -10 ~ +40â | ă |
| Operate humidity | < +90% | Relative humidity |
| Storage temperature | -40 ~ +70â | |
| Storage humidity | 0 ~ +95% | Relative humidity |
| Cooling | Natural | |
| Vibration resistance | 5MM/50HZ/600S | Non-operating condition |
| Impact resistance | 1 meter drop test 3 times | Non-operating condition |
| 4.Mechanical | ||
| Weight | 400g | |
| Size | 175X72X40 |
Casing only |
| Connector | Refer to order | |
| 5.Safety | ||
| Max. temperature rise | < 40â on casing | |
| Safety approval | CE/cTUVus/CCC/PSE | |
| MTBF | 30000H | |
| ESD | 8.0KV | |
| Hi-Pot Insulation | i/p to o/p: 3000V (1 min) | |